HP-[RANGE]-INPUT

Product and Ordering Information

Universal PC-Programmable 2-wire transmitter

Transmitters 1 | Thermo Sensors Transmitters 2 | Thermo Sensors

IPAQ C330 is a universal, isolated, temperature transmitter with additional voltage and resistance input. Its robust design and high quality gives excellent performance and accuracy also under harsh conditions.

IPAQ C330 supports communication via NFC® (Near-field communication) and Bluetooth® which makes it possible to configure and monitor the transmitter remotely.

  • High accuracy and long term stability
  • 50-point Customized Linearization and Callendar-Van Dusen
  • Accepts RTD, T/C, mV and Ω
  • Sensor error and system (sensor/transmitter) error correction for highest total accuracy
  • Low temperature drift
  • Configuration via USB or NFC without external power
  • Runtime counter – hour counter for elapsed operational time
  • Rugged design tested for 10 g vibrations
  • High security – Password protection and date of changes logged
Specification Details
Input RTD 2-, 3-, 4-wire connection
RTD Types & Ranges Pt100 (α =0.00385): -200 to +850 °C / -328 to +1562 °F
PtX (10 ≤ X ≤ 1000, α =0.00385): Upper range depends on X-value
Pt100 (α =0.003916): -200 to +850 °C / -328 to +1562 °F
Ni100¹, Ni120²: -60 to +250 °C / -76 to +482 °F
Ni1000¹: -50 to +180 °C / -58 to +356 °F
Cu10³: -50 to +200 °C / -58 to +392 °F
Input Resistance / Potentiometer 0 to 10000 Ω / 100 to 10000 Ω
Input Thermocouples Types B, C, D, E, J, K, N, R, S, T
Input mV -10 to +1000 mV
Sensor Failure Upscale (≥21.0 mA) or downscale (≤3.6 mA) action
Adjustments – Zero Any value within range limits
Adjustments – Minimum Spans Pt100, Pt1000, Ni100, Ni1000: 10 °C / 18 °F
Potentiometer: 10 Ω
T/C, mV: 2 mV
Output 4-20 mA / 20-4 mA, temperature linear
Operating Temperature -40 to +85 °C / -40 to +185 °F
Galvanic Isolation 1500 VAC, 1 min
Power Supply IPAQ C330: 8.0…36.0 VDC
IPAQ C330X: 8.0…30.0 VDC
Intrinsic Safety IPAQ C330X ATEX: II 1 G Ex ia IIC T6…T4 Ga⁴
IPAQ C330X IECEx: Ex ia IIC T6…T4 Ga⁴
IPAQ C330X cFMus: IS CL I Div 1 GP A-D, T6…T4 ;
Cl I Zn 0 AEx/Ex ia IIC T6…T4 Ga⁴
Typical Accuracy ±0.08°C or ±0.08% of span
Connection Head DIN B or larger
1 DIN 43760,  2 Edison No.7,  3 Edison No.15,  4 For Tambient, see the manual
C330 Tsc Catalog Sheet 2025 02 25 Input Connections - Thermo Sensors

Ordering Information

HP-[RANGE]-INPUT

HP-[RANGE]-INPUT-ATEX

HP-[RANGE]-INPUT-FM

HPH-[RANGE]-INPUT

Product and Ordering Information

Universal HART-Compatible 2-wire Transmitter

Transmitters 3 | Thermo Sensors Transmitters 4 | Thermo Sensors

IPAQ C530 is a modern, HART® temperature transmitter developed to meet the highest standards of accuracy and reliability. A universal transmitter compatible with RTD, thermocouples, voltage and potentiometer sensors. It is fully compatible with HART® 7 and offers extended diagnostic information, for example device error, sensor and wiring conditions. IPAQ C530 supports communication via NFC® (Near-field communication) and Bluetooth® which makes it possible to configure and monitor the transmitter remotely.

  • High accuracy and long term stability
  • Accepts RTD, T/C, mV and ohm
  • Sensor error and system (sensor/transmitter) error correction
  • 50-point Customized Linearization and Callendar-Van Dusen
  • Rugged design tested for 10 g vibrations
  • Configuration via USB, without external power
  • Runtime counter – hour counter for elapsed operational time
  • Communicates with HART Communicator or PC via modem
  • Integrated in Emerson AMS and Siemens PDM systems
Specification Details
Input RTD 2-, 3-, 4-wire connection
RTD Types & Ranges Pt100 (α =0.00385): -200 to +850 °C / -328 to +1562 °F
PtX (10 ≤ X ≤ 1000, α =0.00385): Upper range depending on X-value
Pt100 (α =0.003916): -200 to +850 °C / -328 to +1562 °F
Ni100¹, Ni120²: -60 to +250 °C / -76 to +482 °F
Ni1000¹: -50 to +180 °C / -58 to +356 °F
Cu10³: -50 to +200 °C / -58 to +392 °F
Input Resistance / Potentiometer 0 to 10000 Ω / 100 to 10000 Ω
Input Thermocouples Types B, C, D, E, J, K, N, R, S, T
Input mV -10 to +1000 mV
Sensor Failure Upscale (≥21.0 mA) or downscale (≤3.6 mA) action
Adjustments – Zero Any value within range limits
Adjustments – Minimum Spans Pt100, Pt1000, Ni100, Ni1000: 10 °C / 18 °F
Potentiometer: 100 Ω
T/C, mV: 2 mV
Output 4-20 / 20-4 mA, temperature linear
Operating Temperature -40 to +85 °C / -40 to +185 °F
Galvanic Isolation 1500 VAC, 1 min
Power Supply IPAQ C530: 8.5…36.0 VDC
IPAQ C530X: 8.5…30.0 VDC
Intrinsic Safety IPAQ C530X ATEX: II 1 G Ex ia IIC T6…T4 Ga⁴
IPAQ C530X IECEx: Ex ia IIC T6…T4 Ga⁴
IPAQ C530X cFMus: IS CL I Div 1 GP A-D, T6…T4 ;
Cl I Zn 0 AEx/Ex ia IIC T6…T4 Ga⁴
Typical Accuracy ±0.08°C or ±0.08% of span
Connection Head DIN B or larger
IEC 60751, α=0.00385 and Pt100 acc. to JIS 1604, α=0.003916 ;  DIN 43760 ;  Temperature, resistance or voltage linear, customized linearization possible ;  For Tambient, see the manual
C530 Catalog Sheet 2025 02 25 Input Connections 1 - Thermo Sensors

Ordering Information

HPH-[RANGE]-INPUT

HPH-[RANGE]-INPUT-ATEX

HPH-[RANGE]-INPUT-FM

« Previous